Coefficient of performance (COP and SCOP)

The ratio of heat a heat pump delivers to the electricity it uses; SCOP is the same ratio averaged over a whole heating season.

By Eugene SerbinUpdated

The coefficient of performance (COP) is the amount of heat a heat pump delivers divided by the amount of electricity it uses to do so. A COP of 3 means the pump supplies 3 kilowatt-hours (kWh) of heat for every 1 kWh of electricity, which is sometimes written as 300% efficiency. The seasonal coefficient of performance (SCOP) is the same ratio averaged over a typical heating season.

COP, SCOP and SPF

Measure What it describes
COP Efficiency at one moment, under fixed test conditions (a set outdoor and water temperature)
SCOP Expected average over a heating season, calculated from lab tests and standard climate data
SPF (seasonal performance factor) Efficiency actually measured over time in a real building

A single COP figure can flatter a heat pump because it is often quoted at mild outdoor temperatures. SCOP is a better guide to yearly running costs, and a measured SPF is the most realistic of all because it reflects the real house, the installation and how the system is used.

What changes the figure

  • Outdoor temperature. The colder the air or ground, the harder the pump works, so COP drops in a cold snap.
  • Flow temperature. The hotter the water sent to radiators, the lower the COP. Larger radiators or underfloor heating let the system run cooler and more efficiently.
  • Design and set-up. Correct sizing and controls matter as much as the unit itself.

UK rules

To be eligible for the Boiler Upgrade Scheme in England and Wales, an air-to-water or ground source heat pump must have a SCOP of at least 2.8, under the scheme’s regulations. The rules can change, so check GOV.UK for the current requirements; this is general information, not advice.

Read more: Renewable energy at home: what works in a UK house.